CRCST Departmental Considerations practice questions
Work-area temperature, humidity and air flow, dress code and traffic control, the regulations and standards that govern sterile processing, record keeping, and quality assurance programs. This domain is about 15% of the exam. Try each question, then open the answer.
Read the Departmental Considerations study guide
Question 1
- Negative pressure, with all air exhausted outdoors
- Positive pressure, so air flows out into the hallway
- Equal pressure, so no air moves between the rooms
- Negative pressure, with the air recirculated into prep
Show answer
Answer: A. Negative pressure, with all air exhausted outdoors
Decontamination is kept under negative pressure so air flows into the room and contaminants and aerosols stay inside. Its air is exhausted directly outdoors rather than recirculated to other areas.
Question 2
- Report it to the supervisor and document the reading and action
- Prop open the door to the hallway to let cooler air into the room
- Record the reading and check it again at the end of the week
- Move the sterile packs into the decontamination area until it cools
Show answer
Answer: A. Report it to the supervisor and document the reading and action
When temperature or humidity is out of range, the technician reports it promptly so facilities engineering can correct it. The reading and action are documented. The department then follows its policy for assessing any effect on stored items.
Question 3
- At least weekly
- Only when visibly soiled
- At least daily
- Monthly, during deep cleaning
Show answer
Answer: C. At least daily
AAMI ST79 calls for floors and horizontal work surfaces in processing areas to be cleaned at least daily. Other surfaces, such as walls, shelving and vents, are cleaned on a regular schedule set by policy and whenever soiled.
Question 4
- No label, because the bottle stays in one department
- Only the date the bottle was filled must be written on it
- Label the bottle with the product name and its hazards
- A label only if the chemical is classified as a carcinogen
Show answer
Answer: C. Label the bottle with the product name and its hazards
Secondary containers of hazardous chemicals must carry a workplace label that identifies the product and gives its hazard information. The only exception is a portable container meant for immediate use by the employee who filled it. A bottle left out for all shifts does not qualify.
Question 5
- One in scrubs and a hair cover, with long artificial nails
- One in facility-laundered scrubs with all hair covered
- One in street clothes under a long-sleeved cover jacket
- One in scrubs and a hair cover, with a long necklace showing
Show answer
Answer: B. One in facility-laundered scrubs with all hair covered
Department attire is facility-laundered scrubs with all head and facial hair covered. Jewelry is removed or contained, artificial nails are not worn, and nails are kept short. These rules reduce the shedding of hair, skin and microorganisms onto instruments and packages.
Question 6
- Prep and packaging, decontamination, sterilization, sterile storage
- Decontamination, sterile storage, prep and packaging, sterilization
- Sterilization, decontamination, prep and packaging, sterile storage
- Decontamination, prep and packaging, sterilization, sterile storage
Show answer
Answer: D. Decontamination, prep and packaging, sterilization, sterile storage
Instruments move one way, from dirty to clean to sterile: decontamination, then preparation and packaging, then sterilization, then sterile storage. This flow keeps contaminated items from crossing paths with clean and sterile items.
Question 7
- Raise the table to shoulder height so the arms stay lifted
- Skip breaks so the work finishes sooner and standing time is shorter
- Set the work surface near elbow height and use an anti-fatigue mat
- Stand directly on the hard floor for better footing
Show answer
Answer: C. Set the work surface near elbow height and use an anti-fatigue mat
A work surface near elbow height lets the technician work without bending forward or lifting the arms. Anti-fatigue mats reduce strain from long periods of standing. Adjustable tables, task rotation and short breaks also lower the risk of injury.
Question 8
- The FDA and the device's manufacturer
- OSHA, which handles workplace incidents
- The EPA, which oversees environmental hazards
- The Joint Commission only
Show answer
Answer: A. The FDA and the device's manufacturer
FDA's medical device reporting rules come from the Safe Medical Devices Act. Under them, user facilities such as hospitals report device-related deaths to both the FDA and the manufacturer. The report is due within 10 work days of learning of the death. Device-related serious injuries go to the manufacturer, or to the FDA if the manufacturer is unknown. Sterile processing reports such events through the facility's risk management process.
Question 9
- Cover it with correction fluid and write in the right entry
- Scribble over it so the wrong entry cannot be read
- Draw one line through it, write the correct entry, and initial and date it
- Remove the page and copy the log onto a fresh sheet
Show answer
Answer: C. Draw one line through it, write the correct entry, and initial and date it
Records are legal documents. A single line keeps the original entry readable, and the correction is written with the person's initials and the date. This shows what was changed, by whom and when.
Question 10
- It should be completed promptly with objective facts
- It is needed only if the injury requires stitches
- It should say which OR staff member is to blame
- It can wait until the end of the week with other reports
Show answer
Answer: A. It should be completed promptly with objective facts
Incident reports are completed promptly while details are fresh. They state objective facts: what happened, when, where and what was done. The goal is follow-up care and fixing the system, not assigning blame.
Question 11
- Identify the technician at fault so discipline can follow
- Prove the problem began in the OR, not in processing
- Find the underlying process causes and fix them
- Complete a form so the event is closed quickly
Show answer
Answer: C. Find the underlying process causes and fix them
Root cause analysis asks why an event happened until it reaches the underlying system causes, such as training, workload, tools or procedures. The department then changes the process to prevent a repeat. It is not designed to assign individual blame.